T-IED 23kV T-IED 23kV has total functions for metering, monitoring, control,
protection, and interlock, which are needed for substation automation
based on IEC61850.
It’s available to be various and flexible engineering with high speed PLC
functions for the protective functions .
For DI/DO point, it’s possible to check more conditions and control output
By choosing the expanded structure.
T-IED23kV is the next generation power monitoring and protection device
to manage the power system much more conveniently
by embedding IEC61850 communication, PLC logic and other functions.
Main Functions
- Substation automation IED
- Saved accident waveform
- Changeable logic(PLC)
- Supported IEC61850 protocol
- Various measurement
- Control the circuit breaker
- Embedded digital filter(DFT)
- Various monitoring functions
- Real time analysis for Vector
- Analysis for Event |
|
Applied to Korean Electric Power Corporation general standard.(KEPCO)
- A25GS-5945-002102000 Overvoltage IED (GS-5945-0021) - [13-11-30]
- A25GS-5945-002403000 Reclosing Overcurrent protection IED (GS-5945-0024) - [17.1]
- A25GS-5945-002503000 25.8kV Overcurrent protection IED (GS-5945-0025) - [17.1]
- A25GS-5945-002602000 Undervoltage protection IED (GS-5945-0026) - [13-11-30] |
Protective relay
ITEM |
Contents
|
Unbalance over
current Protection |
UBOC(46)
|
Inst.
Over Current Protection |
OCR(50)
|
Time Over Current
Protection |
OCR(51)
|
Inst. Over Current
Ground Protection |
OCGR(50N)
|
Time Over Current
Ground Protection |
OCGR(51N)
|
Under Frequency
Protection |
UFR(81U)
|
Reclosing Protection
|
RCS(79)
|
Over Voltage Protection
|
OVR(59)
|
Under Voltage Projection
|
UVR(27)
|
|
Measurement
ITEM
|
Range
|
Precision
|
Remark
|
Voltage
|
0.0 ~ 999.99KV |
±0.2% |
VZA,B,CN,
Vpos, Vneg |
Current
|
0.0
~ 999.99KA |
±0.2% |
IA,B,CN,
Ipos, Ineg, Iavg |
Active Power
|
0.0
~ 999.99MW |
±1% |
A, B, C, 3P |
Reactive Power
|
0.0
~ 999.99MVAR |
±1% |
A, B, C, 3P |
Apparent power
|
0.0
~ 999.99MVA |
±1% |
A, B, C, 3P |
Active Energy
|
0.00 ~ 9999.99MWH |
±1% |
A, B, C, 3P |
Reactive Energy
|
0.00 ~ 9999.99MVARH |
±1% |
A, B, C, 3P |
Frequency
|
45 ~ 65Hz |
±0.02Hz |
|
Power Factor(PF)
|
-1.000 ~ 1.000 |
±1% |
A, B, C, 3P |
|
Record
Item
|
Contents
|
Remark
|
Event
log(1024 event) |
Log |
Log in/out |
System
|
Value change,
reset |
DI/DO |
Digital I/O |
Protection function operation
|
Trip, Pickup,
... |
Fault
current |
|
Fault
log(1024 event)
Fault wave |
User setting trigger point
|
|
Available
to set the location of Trigger.
Available to set the number of save cycles
(Before/After) |
|
Save the value of Current, Voltage, etc.
and the timing.
|
|
Save COMTRADE format
|
|
Support fault wave view from Manager
|
|
|
General
Spec. (1)
Item
|
Contents
|
Input
|
Rated Frequency
|
50/60 Hz
|
Rated Voltage
|
PT AC110V/√3, 8ch(A/B bus)
|
Rated Current
|
CT 5A, 4ch
|
Rated Control
Power |
DC 125V(±20%)
|
Digital Input |
DC 125V 60points
|
Output
|
POWER |
16 points(Normal Open)
|
Operating
temperature range |
-25℃ ~ + 55℃
|
Relative
humidity |
10% ~ 100%
|
Altitude
|
Under altitude of 1,000m
|
Remark
|
The position without abnormal vibration and any shock.
|
Communication
|
IEC61850-1~10
|
|
General
Spec. (2)
Item
|
Contents
|
CT/PT Module |
CT - 4ch
PT - 8ch |
Relay |
50, 51, 50N,
51N, 46(UBOC), 671, 67D, 67NI, 67ND, 81U,
25 |
Input / Output |
DO - 16EA
DI - 60EA |
Current / Voltage |
Ia, Ib, Ic,
I1, I2, I0
A BUS : Va, Vb, Vc, Vn, V1, V2, V0, Vab,
Vbc, Vca
B BUS : Va, Vb, Vc, Vn, V1, V2, V0, Vab,
Vbc, Vca |
Power
& Frequency |
S, P, Q, PF,
Frequency, kWh (Forward / Reverse),
Kvarh (Forward / Reverse ) |
Real
Time Monitoring |
Vector diagrams
|
I/O
Monitoring |
Digital Input
& Digital Output
Goose Sub, Goose Sub Q
PLC M, S Logic Conditions |
Event
& Fault Wave Recorder |
Event - 1000
EA
Fault wave - 12 EA |
Communication
|
IEC61850 MMS
& GOOSE Service |
Logic
|
Ourselves PLC
logic structure |
|
|
|